9 RH767 HF reader
To programming RH767 HF reader, it needs C++ library. Please get it from below URL.
http://w3.adc.unitech.com.tw/pub/cs/SDK/RH767/RFID_SDK.zip
And get the sample program from the link.
http://w3.tw.ute.com/pub/cs/software/RFID/HF/RFID_HF.zip
9.1 General Function
9.1.1 Get library version
Function Description:
To get the library version.
Function Call:
INT32 RDINTsys_GetAPIVersionString (LPWSTR strVersion);
Parameter:
strVersion: Get the library version.
Return code:
Please refer to section 9.5.
9.1.2 Connect to RFID reader
Function Description:
To create a connection with the reader before control it.
Function Call:
INT32 RDINTsys_OpenReader (BYTE u8COMPort,UINT32 u32Baudrate,CONST LPTSTR
strAccessCode,BYTE u1SecurityMode,UINT32 u32OpenDelayMs,PUINT32 pu32Baudrate)
Parameter:
u8COMPort: The reader’s COM port number (1 – 255)
u32Baudrate: The reader’s baud rate and the defualt is 19200.It supports 9600, 19200,
38400 and 115200.
strAccessCode: The reader’s access code, default is “00000000”
u1SecurityMode: To set use security mode or not.
TURN_ON : Open.
TURN_OFF : Close.
u32OpenDelayMs: The delay time for wait reader initial, we suggest this value is 700.
pu32Baudrate: Receive the current reader’s baud rate, if it is NULL then it will not receive
the value.
Return code:
Please refer to section 9.5.
9.1.3 Close Reader
Function Description:
To finish controlling the reader.
Function Call:
INT32 RDINTsys_CloseReader (BYTE u8COMPort);
Parameter:
u8COMPort: The reader’s COM port number (1 – 255)
Return code:
Please refer to chapter 9.5.